Services Sectors Projects FAQ Request a Quote →
ACMV · HVAC · MEP · Cleanroom · Singapore

Engineering
Services in
Singapore

Winsteam Engineering provides end-to-end ACMV, HVAC, MEP engineering, cleanroom design and validation, and preventive maintenance services across Singapore. One contractor. Full accountability. Since 1994.

BCA & SCDF Compliant
ISO-Aligned Quality
24/7 Emergency Response
Singapore · GST Reg: 199407459M
Service 01

ACMV &
HVAC
Systems

As a licensed ACMV contractor in Singapore, Winsteam provides the full lifecycle of Air Conditioning and Mechanical Ventilation services — from initial design through to long-term operation and maintenance.

We work with all major chilled water system configurations, handle both central plant and distributed ACMV architectures, and deliver CP13-compliant commissioning with complete documentation at handover.

All ACMV works comply with BCA regulations, CP13 (Code of Practice for Air-Conditioning and Mechanical Ventilation in Buildings), and SCDF requirements.

ACMV Design & EngineeringCooling load calculations, equipment selection, BCA submission drawings, and M&E coordination for new and retrofit projects.
Chilled Water Plant InstallationChillers, cooling towers, primary and secondary pumping systems, and full pipework for central ACMV systems.
AHU & FCU WorksSupply, installation, and commissioning of air handling units and fan coil units across all facility types.
ACMV Retrofit & UpgradingEnergy-efficient replacement of ageing systems including refrigerant conversion, VSD retrofits, and CP13 compliance upgrading.
BMS IntegrationACMV controls and building management system integration for centralised monitoring, scheduling, and energy optimisation.
ACMV System Types
Chilled Water (CWS) Variable Refrigerant Flow (VRF) Direct Expansion (DX) Dedicated Outdoor Air (DOAS) Precision Cooling In-Row Cooling
Key Equipment
Centrifugal & Screw Chillers Cooling Towers Air Handling Units (AHU) Fan Coil Units (FCU) CRAC / CRAH Units Exhaust & Supply Fans Energy Recovery Units
Compliance Standards
CP13 (SS 553) BCA Regulations SCDF Fire Code BCA Green Mark ISO 14644
Sectors
Hotels Hospitals Data Centres Commercial Industrial Pharmaceutical
Service 02

MEP
Engineering

Winsteam provides integrated MEP (Mechanical, Electrical, and Plumbing) engineering for buildings across Singapore. Our in-house capability across all three disciplines means one contractor manages your complete building services scope — eliminating the interface risk, cost duplication, and coordination overhead of managing separate mechanical, electrical, and plumbing contractors.

We handle everything from M&E design and BCA submission through to installation, testing, commissioning, and handover documentation. See our guide on choosing an M&E contractor in Singapore for how this scope compares to an ACMV-only engagement.

Mechanical SystemsACMV and plumbing — chilled water, domestic water supply, drainage, and sanitary systems.
Electrical SystemsLV distribution, lighting design, power outlet planning, and earthing for commercial and industrial buildings.
Fire ProtectionSprinkler systems, fire suppression, wet risers, and coordination with SCDF requirements.
Controls & BMSBuilding management system design and integration — ACMV controls, energy metering, and building automation.
M&E CoordinationFull coordination with architectural, structural, and specialist teams — clash detection and shop drawing review.
MEP Scope
ACMV Design Plumbing & Drainage LV Electrical Lighting Design Fire Sprinkler Systems Fire Suppression BMS / BACS Energy Metering M&E Coordination
Deliverables
BCA Submission Drawings Shop Drawings As-Built Drawings O&M Manuals Commissioning Reports Compliance Certificates
Project Types
New Build MEP Office Fit-Out M&E Retail & F&B Industrial Facilities Healthcare M&E Hospitality Refurbishment
Service 03

Cleanroom
Design &
Validation

Winsteam designs, builds, and validates cleanrooms to ISO 14644 standards for pharmaceutical manufacturing, semiconductor production, medical device assembly, and laboratory environments across Singapore.

Our cleanroom scope covers the ACMV infrastructure (HEPA filtration, pressurisation, temperature and humidity control), the physical envelope (walls, ceilings, floors, airlocks), environmental monitoring systems, and full validation documentation — IQ, OQ, and PQ protocols aligned to GMP requirements.

Single-point accountability from design through validated handover.

Cleanroom ACMV DesignHEPA and ULPA filtration, unidirectional and turbulent flow systems, pressurisation cascades, and temperature and humidity control to ISO 14644 specifications.
Cleanroom ConstructionCleanroom envelope installation — sandwich panel walls and ceilings, epoxy or vinyl flooring, pass-throughs, and airlocks.
Environmental Monitoring SystemsParticle counters, temperature and humidity sensors, differential pressure monitoring, and integration with BMS or dedicated EMS platforms.
Validation (IQ/OQ/PQ)Installation qualification, operational qualification, and performance qualification documentation for GMP-regulated cleanroom environments.
ISO Cleanroom Classes We Build
ISO 5
Class 100
Aseptic filling, sterile manufacturing, critical drug compounding
ISO 6
Class 1,000
Semiconductor fabrication, optics manufacturing, sterile garment staging
ISO 7
Class 10,000
Pharmaceutical manufacturing, medical device assembly, electronics
ISO 8
Class 100,000
General pharmaceutical operations, R&D laboratories, biotech facilities
Applications
Pharmaceutical GMP Semiconductor Medical Devices Biotech / R&D Labs Aerospace Hospital Pharmacies
Service 04

Preventive
Maintenance

Planned preventive maintenance (PPM) contracts tailored to your facility — keeping ACMV and building services systems running efficiently, safely, and in compliance year-round. Includes 24/7 emergency call-out for critical facilities.

ACMV Maintenance
Scheduled servicing of all ACMV equipment — from chilled water plant down to individual FCUs and AHUs.
  • Chiller servicing and water treatment
  • Cooling tower cleaning and dosing
  • AHU coil and filter servicing
  • FCU cleaning and drain pan inspection
  • Refrigerant pressure and leak checks
  • Ductwork and diffuser inspection
  • Thermostatic and controls calibration
MEP Building Services Maintenance
Comprehensive building services maintenance covering mechanical, electrical, and plumbing systems.
  • BMS monitoring and alarm management
  • Fire sprinkler and suppression inspection
  • Pump and motor servicing
  • Electrical panel and switchgear inspection
  • Plumbing and drainage maintenance
  • Lighting inspection and replacement
  • Statutory compliance reporting
Cleanroom Maintenance
Specialist maintenance and monitoring for ISO-classified cleanroom environments requiring GMP compliance.
  • HEPA filter integrity testing (DOP/PAO)
  • Particle count monitoring and trending
  • Pressurisation cascade verification
  • Temperature and humidity calibration
  • EMS sensor calibration and certification
  • GMP compliance documentation
  • Requalification support after changes
Frequently Asked Questions

Services FAQ

Common questions about Winsteam's engineering services in Singapore.

Have a specific question? Call +65 9380 8176 or email winsteam@winsteam.sg.

Winsteam offers design, supply, installation, commissioning, retrofit, and preventive maintenance of ACMV and HVAC systems. This covers chilled water plants, AHUs, FCUs, ductwork, BMS integration, and CP13-compliant testing and commissioning. We serve hotels, hospitals, data centres, commercial offices, industrial facilities, and pharmaceutical cleanrooms.
Yes. Winsteam provides integrated MEP services covering mechanical (ACMV and plumbing), electrical (LV distribution, lighting), fire protection, BMS and controls integration, and full M&E coordination. Single-point accountability across all building services disciplines reduces interface risk and project complexity.
Winsteam designs and builds ISO Class 5 through ISO Class 8 cleanrooms for pharmaceutical GMP, semiconductor, medical devices, and biotech R&D environments. Scope covers ACMV infrastructure (HEPA filtration, pressurisation, temperature and humidity control), cleanroom envelope, environmental monitoring systems, and full IQ/OQ/PQ validation documentation.
We tailor each PPM contract to your facility's equipment inventory and operational requirements — agreeing a maintenance schedule (monthly, quarterly, bi-annual, and annual visits), assigning a dedicated service team, and providing compliance reporting at each visit. Contracts include 24/7 emergency call-out response for hotels, data centres, hospitals, and pharmaceutical facilities.
Yes. The majority of our retrofit and maintenance work is carried out in occupied or partially occupied buildings — hotels, hospitals, and commercial offices that cannot shut down. We plan phased works carefully, schedule intrusive activities during low-occupancy periods, and coordinate closely with facilities teams to minimise disruption.
Get in Touch

Ready to Discuss
Your Project?

Tell us about your scope and we'll respond within one business day. Site surveys available for complex ACMV, MEP, and cleanroom projects.

+65 9380 8176  ·  winsteam@winsteam.sg  ·  111 Tampines Rd, #07-01, Singapore 535133